Title of article :
Operation of thin metal foil bolometer for radiation loss measurement in a toroidal plasma on Heliotron E
Author/Authors :
Besshou، نويسنده , , S and Morimoto، نويسنده , , S and Fujita، نويسنده , , N and Kondo، نويسنده , , K and Mizuuchi، نويسنده , , T and Nagasaki، نويسنده , , K and Okada، نويسنده , , H and Sano، نويسنده , , F and Zushi، نويسنده , , H and Obiki، نويسنده , , T، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
5
From page :
311
To page :
315
Abstract :
A thin metal foil bolometric detector for time-resolved radiation loss measurements in the Heliotron E toroidal plasma confining experiment is described. The bolometer consists of a 10 or 50 gm thick stainless-steel radiation absorber, an insulation layer and a nickel resistor pattern. The bolometric detector, its electronics, the construction of the array and installation under vacuum and high-temperature conditions in toroidal plasma devices are reported. The physical principles of detection of the wavelength integrated total radiative loss from plasmas are described. The detector array consists of wide-angle bolometers to monitor the time-resolved total radiative loss power and a recently tested 17-channel bolometer array camera to measure the profiles of radiative loss. Typical radiative loss measurements in helical plasmas on Heliotron E with ECRH and NBI heating are presented.
Journal title :
Fusion Engineering and Design
Serial Year :
1997
Journal title :
Fusion Engineering and Design
Record number :
2363428
Link To Document :
بازگشت