Design of superheterodyne radiometer as ECE diagnostic for electron temperature profile measurement in SST-1
Author/Authors :
Pandya، نويسنده , , H.K.B and Atrey، نويسنده , , P.K and Govindarajan، نويسنده , , J and Mattoo، نويسنده , , S.K، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
4
From page :
469
To page :
472
Abstract :
This paper presents the design of an eight-channel W band radiometer as an electron cyclotron resonance (ECE) diagnostic to measure the electron temperature for phase I (Bt0 = 1.5 T) operation of SST-1. A double-sideband (DSB) mixer cum power divider method is used to cover the full range of ECE frequencies. The noise figure, sensitivity and expected output signal of the radiometer are estimated and a calibration technique is discussed. A time resolution of 5 μs and a spatial resolution of 0.6 cm for 2fce = 70 GHz are achieved by this radiometer.
Journal title :
Fusion Engineering and Design
Serial Year :
1997
Journal title :
Fusion Engineering and Design