Title of article :
Critical heat flux test on saw-toothed fin duct under one-sided heating conditions
Author/Authors :
Ezato، نويسنده , , K and Suzuki، نويسنده , , S and Sato، نويسنده , , K and Taniguchi، نويسنده , , M and Hanada، نويسنده , , M and Araki، نويسنده , , M and Akiba، نويسنده , , M، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
Critical heat flux (CHF) tests on a new type of rectangular cooling tube, ‘saw-toothed fin duct, SFD’ for high heat flux components were performed under one-sided heating conditions. The tube has internal triangle fins at the heating side to enhance the CHF characteristics. Hydraulic conditions were as follows: axial flow velocity ranged from 2 to 12 m/s. Local pressure at the center of the test sample was 1 MPa and inlet water temperature was 21–25 °C. In the present work, SFD, which has a fin height of 3.46 mm and an installation angle of the fin of 70°, results in the highest CHF of 43 MW/m2 at the axial flow velocity of 10 m/s. This value is 1.3 times higher than that obtained with a Hypervapotron.
Keywords :
Saw-toothed fin duct , Critical heat flux (CHF) , One-sided heating conditions , Hypervapotron
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design