Abstract :
Design and manufacturing of the model cryopump for ITER-FEAT have been finished. After acceptance tests at the contractorʹs premises the pump was installed in the TIMO-facility which was prepared for testing the pump under ITER-FEAT relevant operating conditions. The procedures for the final acceptance tests are described. Travelling time, positioning accuracy and leak rate of the main valve are within the requirements. The heat loads to the 5 and 80 K circuits are a factor two better than the designed values. The maximum pumping speeds for H2, D2, He, Ne were measured. The value of 58 m3/s for D2 is well above the contractual required value of 40 m3/s.