• Title of article

    Dual-fluid-hybrid power plant co-powered by low-temperature geothermal water

  • Author/Authors

    Borsukiewicz-Gozdur، نويسنده , , Aleksandra، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    7
  • From page
    170
  • To page
    176
  • Abstract
    Three variants of power plants fuelled or co-fuelled by geothermal water have been assessed, with the aim of making the best use of the energy contained in a stream of 80–120 °C geothermal water. Heat-flow calculations for three power plant types, namely an Organic Rankine Cycle (ORC) power plant, a dual-fluid-hybrid power plant and a single-fluid hybrid-fuelled power plant, are presented. The analysis shows the thermodynamic benefits, in terms of the extent of using the thermal energy of low-temperature geothermal water, that arise from utilizing hybrid and dual-fluid-hybrid power plants rather than ORC power plants. The dual-fluid plant optimizes the use of the geothermal water, but the hybrid plant makes the best overall utilization of the energy compared to separate ORC and fuel-fired plants.
  • Keywords
    Working fluid , Power plant , Low-temperature Rankine cycle , Organic Rankine cycle , Geothermal , Hybrid power plant
  • Journal title
    Geothermics
  • Serial Year
    2010
  • Journal title
    Geothermics
  • Record number