• Title of article

    Design of the ITER torus cryopump

  • Author/Authors

    Mack، نويسنده , , A and Antipenkov، نويسنده , , A and Boissin، نويسنده , , J.C and Day، نويسنده , , Chr and Gross، نويسنده , , S and Haas، نويسنده , , H and Hauer، نويسنده , , V and Murdoch، نويسنده , , D.K and Waldenmaier، نويسنده , , Th، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    5
  • From page
    611
  • To page
    615
  • Abstract
    The cryopump concept for the ITER 2001 proposed by ITER-JCT was assessed. Some modifications were recommended. For these modified arrangements, Monte-Carlo calculations were performed to define the pumping probability of the cryopump together with the divertor duct. Results show that the ITER requirement can be fulfilled with small restraints if the pump inlet diameter is enlarged to 1000 mm and the neutron shield in the duct is taken out.
  • Keywords
    Torus cryopump , TIMO tests , ITER
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2002
  • Journal title
    Fusion Engineering and Design
  • Record number