Title of article
Development of carbon sheet pump for control of hydrogen recycling in the GAMMA 10 tandem mirror
Author/Authors
Ishimoto، نويسنده , , Yuki and Nakashima، نويسنده , , Yousuke and Sagara، نويسنده , , Akio and Yoshikawa، نويسنده , , Masayuki and Yatsu، نويسنده , , Kiyoshi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
4
From page
429
To page
432
Abstract
The pumping characteristic of carbon sheet pump (CSP) under the condition of high heat and particle load (several MW/m2 and 2.5×1021 H/m2 at the beam center, respectively) is described. Heat transfer calculation is performed for the sake of estimation of the temperature rise. The result shows a high heat conductive C/C material is suitable for this purpose under the condition. Pumping experiments proved that the pumping effect of CSP on neutral beam and recovery of the effect by regeneration experiment by the use of neutral beam injector (21 keV, 20 A) as a high heat and particle source. These results indicate that CSP is applicable under the condition of high heat and particle load.
Keywords
recycling , thermal design , Gamma 10 , carbon
Journal title
Fusion Engineering and Design
Serial Year
2003
Journal title
Fusion Engineering and Design
Record number
2369095