Title of article :
The ground fault detection system for the Tore Supra toroidal pump limiter
Author/Authors :
Zunino، نويسنده , , K. and Cara، نويسنده , , P. and Fejoz، نويسنده , , P. and Hourtoule، نويسنده , , J. and Loarer، نويسنده , , T. and Pomaro، نويسنده , , N. and Santagiustina، نويسنده , , A. and Spuig، نويسنده , , P. and Villecroze، نويسنده , , F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
5
From page :
1019
To page :
1023
Abstract :
The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding.
Keywords :
Tore Supra , Ground fault , Toroidal pump limiter
Journal title :
Fusion Engineering and Design
Serial Year :
2003
Journal title :
Fusion Engineering and Design
Record number :
2369452
Link To Document :
بازگشت