Title of article :
130 kV 130 A high voltage switching mode power supply for neutral beam injectors—Control issues and algorithms
Author/Authors :
Ganuza، نويسنده , , D. and Garcيa، نويسنده , , F. and Zulaika، نويسنده , , M. and Perez، نويسنده , , A. and Jones، نويسنده , , T.T.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
The company JEMA has delivered to the Joint European Torus (JET facility in Culham) two high voltage switching mode power supplies (HVSMPS) each rated 130 kVdc and 130 A. One HVSMPS feeds the grids of two PINI loads. This paper describes the main control issues and the algorithms developed for the project.
st demanding requirements from the control point of view is an absolute accuracy of ±1300 V and the possibility of performing up to 255 re-applications of the high voltage during a 20 s pulse.
g the output voltage ripple to the specified tolerance has been a major achievement of the control system. Since the output stage is formed of several modules (120) connected in series, their stray capacitance to ground significantly influences the individual contribution of each single module to the global output voltage. Two complementary techniques have been used to balance the effects of the stray capacities.
st re-applications requirement has a significant impact on the intermediate dc link. This section is composed of a capacity of 0.83 F, which feeds the 120 invertor modules. The dc link is fed by a 12 pulse SCR rectifier, whose matching transformers are connected to the 36 kV grid. Every re-application and every voltage shutdown supposes a quasi-instantaneous power step of 17 MW. Fast open loop algorithms have been implemented in order to keep the dc link voltage within acceptable margins.
er, the HVSMPS output characteristics have to be maintained during the rapid and important voltage fluctuations of the 36 kV mains (28–37 kV).
neral control system is based on a Simatic S7 PLC, and a SCADA user interface. Up to 1000 signals are acquired. The control system has shown to be also a useful tool to allow for a rapid and accurate identification of faults and their origin.
Keywords :
Thyristor converter , invertor , Busbars
Journal title :
Fusion Engineering and Design
Journal title :
Fusion Engineering and Design