• Title of article

    Oxygen removal with D2-ICR cleanings after oxidation experiment in HT-7

  • Author/Authors

    Hu، نويسنده , , J.S. and Li، نويسنده , , J.G. and Zhao، نويسنده , , Y.P.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    133
  • To page
    139
  • Abstract
    The effectiveness of D2-ICR cleaning with a pressure up to 0.18 Pa was surveyed on hot walls of 400–470 K for oxygen removal after oxidation experiment in the HT-7 superconducting tokamak. The oxygen removal rate in D2-ICR cleaning was about (7–9) × 1021 O-atoms/h, about 5–10 times higher that that He-ICR cleanings before and after the D2-ICR cleaning. In about 130 min He-ICR and D2-ICR cleanings, about 8 × 1021 O-atoms were removed. After the cleanup, a lot of water still retained in HT-7 vessel and 67 disruptive plasmas were required before obtaining normal plasma. In present experiment, the recovered plasmas were easily controlled and much better than previous report in HT-7 oxidation experiments.
  • Keywords
    ICR , Deuterium , Oxygen removal
  • Journal title
    Fusion Engineering and Design
  • Serial Year
    2007
  • Journal title
    Fusion Engineering and Design
  • Record number

    2369936