Author/Authors :
Liu، نويسنده , , H.J. and Wu، نويسنده , , Y. and Ren، نويسنده , , Zh. B. and Shi، نويسنده , , Y. and Chen، نويسنده , , J.L. and Long، نويسنده , , F. and Yu، نويسنده , , M. and Qian، نويسنده , , L.، نويسنده ,
Abstract :
A new facility had been set up to test the low temperature properties of the short sample of the small-size cable-in-conduit conductor (CICC). The facility consisted of the background magnet which could provide 7 T centric magnetic field, a 50 kA superconducting transformer which provided sample current, a 500 W/4.5 K helium refrigerator which produced both the liquid helium (LHe) and supercritical helium (SHe). An ITER CC conductor short sample was prepared and measured in this testing system. Tcs of 7.02 K (@4.1 T, 10 kA) and Ic of 8.9 kA (@4.1 T, 7.06 K) were measured.