Title of article :
On the theoretical–numerical study of the ITER Upper Port Plug structure hydraulic behaviour under steady state and draining and drying transient conditions
Author/Authors :
Di Maio، نويسنده , , P.A. and Paradiso، نويسنده , , D. and DellʹOrco، نويسنده , , G. and Pitcher، نويسنده , , C.S. and Kalish، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
16
From page :
2983
To page :
2998
Abstract :
The ITER diagnostic Upper Port Plug (UPP) is a water-cooled stainless steel structure aimed to integrate within vacuum vessel the plasma diagnostic systems, shielding them from neutron and photon irradiation. Due to the very intense heat loads expected, a proper cooling circuit has been designed to ensure an adequate UPP cooling with an acceptable thermal rise and an unduly high pumping power and to perform its draining and drying procedure by injection of pressurized nitrogen. retical research activity has been launched at the Department of Nuclear Engineering of the University of Palermo aiming to investigate the hydraulic behaviour of the UPP Trapezoid Section cooling circuit under steady state conditions and during its draining and drying transient procedure. The research activity has been performed following a theoretical–computational approach and adopting the RELAP5 thermal–hydraulic system code. apezoid Section cooling circuit characteristic functions have been derived under steady state conditions at various coolant temperatures for both the coolant flow paths at the present under consideration for this circuit. The distributions of coolant mass flow rates along the channels of the cooling circuit have been calculated too. Results show that the flow path characterized by right plate inlet has improved hydraulic performances. ansient behaviour of the Trapezoid Section cooling circuit has been investigated during the draining and drying operational transient procedure, considering realistic operative scenarios, for both the coolant flow paths at the present under consideration for the cooling circuit. In particular, it has been found out that the recently proposed flow path seems to allow the complete draining of the Trapezoid Section circuit, eliminating the need for the drying procedure.
Keywords :
ITER Upper Port Plug , Thermal–hydraulic , Draining and drying
Journal title :
Fusion Engineering and Design
Serial Year :
2011
Journal title :
Fusion Engineering and Design
Record number :
2370163