Title of article :
Thermo-hydraulic analysis of the generic equatorial port plug design
Author/Authors :
Rodrيguez، نويسنده , , E. and Guirao، نويسنده , , Arturo J. Miranda-Ordieres، نويسنده , , J. and Cortizo، نويسنده , , J.L. and Iglesias، نويسنده , , S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
10
From page :
13
To page :
22
Abstract :
The port-based ITER diagnostic systems are housed primarily in two locations, the equatorial and upper port plugs. The port plug structure provides confinement function, maintains ultra-high vacuum quality and the first confinement barrier for radioactive materials at the ports. The port plug structure design, from the ITER International Organisation (IO), is cooled and heated by pressurized water which flows through a series of gun-drilled water channels and water pipes. The cooling function is required to remove nuclear heating due to radiation during operation of ITER, while the heating function is intended to heat up uniformly the machine during baking condition. The work presented provides coupled thermo-hydraulic analysis and optimization of a Generic Equatorial Port Plug (GEPP) structure cooling and heating system. The optimization performed includes positioning, minimization of number and size of gun drilled channels, complying with the flow and functional requirements during operating and baking conditions.
Keywords :
Thermo-hydraulic , Finite element , ITER , Equatorial port plug
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design