Title of article :
Electromagnetic analysis of ITER generic equatorial port plug designs during three plasma current disruption cases
Author/Authors :
Guirao، نويسنده , , J. and Rodrيguez، نويسنده , , E. and Ordieres، نويسنده , , J. and Cabanas، نويسنده , , M.F. and Garcيa، نويسنده , , C.H. Rojas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
15
From page :
141
To page :
155
Abstract :
Electromagnetic phenomena due to plasma current disruptions are the cause for the main mechanical operation loads over the ITER equatorial level port plug structures. aper presents a detailed finite element simulation and analysis of the transient electromagnetic effects of three different plasma current disruption cases over three designs of diagnostic shielding module (DSM) structure. The DSMs are contained into and supported by the generic equatorial port plug (GEPP) analyzed structure. ree plasma disruption cases studied were: major disruption upwards linear decay in 36 ms (MD UP LIN36), vertical displacements events, upwards and downwards linear decay in 36 ms (VDE UP LIN36 and VDE DW LIN36). A detailed analysis for GEPP structure and three DSM-first wall (FW) designs (horizontal and vertical drawers and monoblock) is also presented in order to extract the Eddy current distribution on these devices and thus the resultant electromagnetic forces and moments acting on them.
Keywords :
electromagnetic , Equatorial port plug , ITER , Finite element , Transient analysis
Journal title :
Fusion Engineering and Design
Serial Year :
2012
Journal title :
Fusion Engineering and Design
Record number :
2370184
Link To Document :
بازگشت