Abstract :
The first ITER Main Busbar (MBCN1) and Correction Busbar (CBCN1) conductor samples were manufactured in ASIPP and tested in the SULTAN facility. This paper introduces the sample manufacture, including strand, cabling, jacketing and sample preparation, and discusses the performance of MBCN1 and CBCN1 conductors. The testing results show that both samples have high Tcs, and meet the ITER requirement. the ITER acceptance standard Tcs of MB conductor was changed to 6.7 K at 45.5 kA/3.9 T. The performance of MBCN1 conductor after cyclic load fits the ITER requirement, but the sample was only tested at 57 kA/2.75 T before cycling test. Using some hypothesis and equation to extrapolate the Tcs performance of MBCN1 conductor before cycling test, the result also fits the ITER requirement. CN1 conductor, the central line of the central cooling spiral shifted about 1.3 mm during the cabling. The deviation causes an increase of the max self-field by about 0.005 T, which could not influence the CBCN1 conductor real Tcs performance at peak field.
Keywords :
ITER , Main Busbar , Corrector Busbar , TCS , Self-field
Journal title :
Fusion Engineering and Design
Serial Year :
2013
Journal title :
Fusion Engineering and Design
Record number :
2370410
Link To Document :
بازگشت