Title of article
Hotspot temperature calculation and quench analysis on ITER busbar
Author/Authors
Rong، نويسنده , , J. and Huang، نويسنده , , X.Y. and Song، نويسنده , , Y.T. and Wu، نويسنده , , S.T.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2014
Pages
4
From page
2971
To page
2974
Abstract
This paper describes the analysis of ITER feeder busbar, the hotspot temperature of busbar is calculated by classical method in the case of 0%, 50%, 75% and 100% extra copper (copper strands). The quench behavior of busbar is simulated by 1-D Gandalf code, and the MQE (minimum quench energy) is estimated in classical method as initial external heat in Gandalf input file. The temperature and the normal length of conductor are analyzed in the case of 0%, 50% and 100% extra copper and no helium. By hotspot temperature, conductor temperature and normal length are contrasted in different extra copper cases, it is shown that the extra copper play an important role in quench protecting.
Keywords
Hotspot temperature , Normal length , Minimum quench energy
Journal title
Fusion Engineering and Design
Serial Year
2014
Journal title
Fusion Engineering and Design
Record number
2370999
Link To Document