Author/Authors :
Darekar، نويسنده , , Mayur and Sen، نويسنده , , Nirvik and Singh، نويسنده , , K.K. and Mukhopadhyay، نويسنده , , S. and Shenoy، نويسنده , , K.T. and Ghosh، نويسنده , , S.K.، نويسنده ,
Abstract :
Liquid–liquid extraction experiments have been carried out in two different types of microchannels using water (Zn) D2EHPA + dodecane system, a standard reactive extraction system recommended for evaluation of liquid–liquid extraction equipment. The microchannels used in the experiments are a t-junction serpentine microchannel and a split and recombine microchannel. Effects of O/A ratio and residence time on overall volumetric mass transfer coefficient have been studied and an attempt has been made to explain the experimental trends with the help of liquid–liquid flow patterns observed by using a high speed image acquisition system. Correlations relating overall volumetric mass transfer coefficients to O/A ratio and velocity are reported for both the microchannels.
Keywords :
Mass transfer coefficient , Microchannel , Serpentine , D2EHPA , Split and recombine