Title of article :
Determining the amount of Acrylamide in Potato Chips Using Xanthydrol as a Derivative Representative with Gas Chromatography-Mass Spectrometry
Author/Authors :
Zokaei، Maryam نويسنده Master student of Food Biosciences and Technology, National Nutrition & Food Technology Research Institute, Faculty of Nutrition Science & Food Technology, Shahid Beheshti University of Medical Science, Tehran, Iran Zokaei, Maryam , Kamankesh، Marzieh نويسنده PhD student, Iran University of Science and Technology, Tehran, Iran Kamankesh, Marzieh , SHOJAEI، Saeideh نويسنده Dept. of Medical Parasitology and Mycology, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran SHOJAEI, Saeideh , Mohammadi، Abdorreza نويسنده ,
Issue Information :
فصلنامه با شماره پیاپی 7 سال 2016
Pages :
6
From page :
51
To page :
56
Abstract :
Background and Objectives: In the production process of foods rich in carbohydrates and some other foods containing precursors of acrylamide formation, there is the possibility of acrylamide creation, which is a mutagen and carcinogen material. This study aims to introduce and optimize a new method for determining acrylamide in potato chips using xanthydrol as a derivative representative with gas chromatography-mass spectrometry. Materials and Methods: Important factors in the derivatization and measurement processes were optimized using the one-factor-at-a-time method. The peak areas were assumed as the GC-MS response to evaluate the extraction efficiency of acrylamide, and optimization for all tests was performed two times. Figures of merit of the proposed method were evaluated. The amount of acrylamide in four potato chips samples, obtained from the market in Tehran city, was determined using the proposed method. Results: The optimum amounts of effective parameters, including derivatization temperature at 25oC, derivatization time (40 min), xanthydrol volume (40 µL), extracted solvent volume (500 µL) and pH=7 were determined. The figures of merit for the proposed method were at the ideal range. The maximum and minimum amounts of acrylamide in the chip samples were also measured. Conclusions: The performance and reliability of proposed method as a simple, efficient and rapid method for determining acrylamide in potato chip samples were demonstrated.
Journal title :
Nutrition and Food Sciences Research
Serial Year :
2016
Journal title :
Nutrition and Food Sciences Research
Record number :
2380881
Link To Document :
بازگشت