• Title of article

    The effect of inlet conditions on the air side hydraulic resistance and flow maldistribution in industrial air heaters

  • Author/Authors

    Hoffmann-Vocke، نويسنده , , Jonas and Neale، نويسنده , , James and Walmsley، نويسنده , , Michael، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    12
  • From page
    834
  • To page
    845
  • Abstract
    Experimental system hydraulic resistance measurements on a scale air heater unit have highlighted the excessive hydraulic resistance of typical industry configurations. Both poor header inlet conditions and large header expansion angles are shown to contribute to system hydraulic resistance magnitudes 20–100% higher than suitable benchmark cases. Typical centrifugal fan system efficiencies well under 80% multiply the system resistance effects resulting in larger fan power penalties. Velocity profile measurements taken upstream and downstream of the test heat exchanger under flow maldistribution conditions provide insight into the flow maldistribution spreading caused by the heat exchanger resistance. The anisotropic resistance of the plate fin-and-tube heat exchanger is shown to result in resistance induced flow dispersion being concentrated in the axis parallel to the plate fins.
  • Keywords
    Plate fin-and-tube heat exchangers , Pressure drop , Flow Maldistribution
  • Journal title
    International Journal of Heat and Fluid Flow
  • Serial Year
    2011
  • Journal title
    International Journal of Heat and Fluid Flow
  • Record number

    2381991