An idealized magnet model previously used in a simple coil configuration is applied to a more complicated engineering design problem, where an electromagnetic flow meter in diameter of 500 mm is used with five pairs of coils. The numerical results are compared with measurement data. The difference between theory and experiment and the possible causes of errors are discussed. It is shown that the idealized magnet model is practical for the design and the analysis of the flow meter. The work also shows that the traditional uniform field design based on two dimensional (2D) analysis is not suitable for this kind of flow meter. Thus nonuniform field and 3D analysis is needed.
Keywords :
experimental data , Electromagnetic flow meter , Magnetic-field distribution , Numerical computation