Title of article
Calculation of the Pitot tube correction factor for Newtonian and non-Newtonian fluids
Author/Authors
Etemad، نويسنده , , S.Gh. and Thibault، نويسنده , , J. and Hashemabadi، نويسنده , , S.H.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
8
From page
505
To page
512
Abstract
This paper presents the numerical investigation performed to calculate the correction factor for Pitot tubes. The purely viscous non-Newtonian fluids with the power-law model constitutive equation were considered. It was shown that the power-law index, the Reynolds number, and the distance between the impact and static tubes have a major influence on the Pitot tube correction factor. The problem was solved for a wide range of these parameters. It was shown that employing Bernoulliʹs equation could lead to large errors, which depend on the magnitude of the kinetic energy and energy friction loss terms. A neural network model was used to correlate the correction factor of a Pitot tube as a function of these three parameters. This correlation is valid for most Newtonian, pseudoplastic, and dilatant fluids at low Reynolds number.
Keywords
Velocity measurements , non-Newtonian fluids , Pitot tube
Journal title
ISA TRANSACTIONS
Serial Year
2003
Journal title
ISA TRANSACTIONS
Record number
2382577