Title of article :
Analysis of field-oriented controlled induction motor drives under sensor faults and an overview of sensorless schemes
Author/Authors :
Arun Dominic، نويسنده , , D and Chelliah، نويسنده , , Thanga Raj، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2014
Pages :
15
From page :
1680
To page :
1694
Abstract :
To obtain high dynamic performance on induction motor drives (IMD), variable voltage and variable frequency operation has to be performed by measuring speed of rotation and stator currents through sensors and fed back them to the controllers. When the sensors are undergone a fault, the stability of control system, may be designed for an industrial process, is disturbed. This paper studies the negative effects on a 12.5 hp induction motor drives when the field oriented control system is subjected to sensor faults. To illustrate the importance of this study mine hoist load diagram is considered as shaft load of the tested machine. The methods to recover the system from sensor faults are discussed. In addition, the various speed sensorless schemes are reviewed comprehensively.
Keywords :
field-oriented control , induction motor drives , Review , Mine hoist load , sensorless control