    Farvaresh، Ehsan نويسنده Department of Occupational Health Engineering, School of Public Health,Tehran University of Medical Sciences, Tehran, Iran. Farvaresh, Ehsan , Golbabaei، Farideh نويسنده , , Ghiyaseddin، Mansour نويسنده Department of Occupational Health Engineering, School of Public Health,Tehran University of Medical Sciences, Tehran, Iran. Ghiyaseddin, Mansour , Behdashti، Ali نويسنده Managing Director of Imen Sarv Co. Behdashti, Ali , Nouri-Jaliani، Keramatollah نويسنده Department of Epidemiology & Biostatics, School of Public Health, Tehran University of Medical Sciences, Tehran, Iran. Nouri-Jaliani, Keramatollah , Karimi، Mehrdad نويسنده Traditional Medicine Departments, Faculty of Tradition Medicine , , Tohidi، Saeed نويسنده School of Energy and Environment, Science and Research Campus, Islamic Azad University, Tehran, Iran. Tohidi, Saeed

  • Issue Information
    فصلنامه با شماره پیاپی 0 سال 2014
  • Pages
    6
  • From page
    75
  • To page
    80
  • Abstract

     The Aim of this study was to evaluate the effect of Evaporative Media as gas turbine intake air cooling method on pressure drop of cartridge air filters. This study performed under the laboratory condition, using stainless steel test rig with specified dimensions to investigate the role of evaporative media in air cooling as well as its effects on new and used cartridge filters (as representative of clean and loaded filters). Tests were carried out at three five hours consecutive stages including, warm -dry stage (Ta=35-40°C) and relative humidity ([RH] =10-15%), cold - humid stage (Ta=22-27°C and RH=80 to 85%), and, warm-dry stage (Ta=35-40 °C and RH=10-15%) for 3 consecutive days. Findings showed that using evaporative media caused air intake temperature reduction was equal to 12.5 °C. Total pressure drop of cartridge filters was 5.13±0.84 and 3.86±0.14 mbar for used and new filters, respectively. Results of repeated measure test showed that the differences between new and used filters pressure drop was significant (P=0.001). Combined effects of humidity and dust loading on filters pressure drop demonstrated that cartridge filters were not affected by humidity (P=0.75) and the main reason of pressure drop was due to collected dust on filters. It is concluded that using evaporative media systems is suitable method for cooling gas turbine intake and increase turbine efficiency without any significant increase of filter pressure drop in hot-dry climate.

  • Journal title
    International Journal of Occupational Hygiene ( IJOH)
  • Serial Year
    2014
  • Journal title
    International Journal of Occupational Hygiene ( IJOH)
  • Record number

    2383560