Author/Authors :
Kadier، Abudukeremu نويسنده Department of Chemical and Process Engineering, Faculty of Engineering & Built Environment, National University of Malaysia (UKM), 43600 UKM Bangi, Selangor, Malaysia , , Simayi، Yibadatihan نويسنده Institute of Tropical Agriculture, University Putra Malaysia, 43400 UPM Serdang, Selangor, Malaysia , , Logro?o، Washington نويسنده Centro de Investigaci?n de Energ?as Alternativas y Ambiente, Facultad de Ciencias, Escuela Superior Politécnica de Chimborazo, Panamericana Sur Km 1 1/2, Chimborazo EC060155, Ecuador , , Sahaid Kalil، Mohd نويسنده Department of Chemical and Process Engineering, Faculty of Engineering & Built Environment, National University of Malaysia (UKM), 43600 UKM Bangi, Selangor, Malaysia. ,
Abstract :
The Microbial electrolysis cell (MEC) is one of the promising and cutting-edge technologies for generating hydrogen from wastewater through biodegradation of organic waste by exoelectrogenic microbes. In MECs the operational parameters,such as applied voltage (Eap), anode surface area, anode-cathode distance, and N2 /CO2 volume ratio have a significant impact on hydrogen yield and production. In the present study, to enhance current and hydrogen production of MECs, the effects
of key operational conditions on the MEC performance were extensively investigated. The optimal operating condition for hydrogen production in MECs was determined as: the optimum applied voltage of 1.1 V, an anode surface area of 94 (cm2), an anode-cathode distance of 1.5 (cm), and a N2 /CO2 volume ratio of 4:1. With these optimum conditions, the maximum H2 volume, current density and hydrogen production rate (HPR) of the MEC reached to 270.09 mL, 314.01 ± 2.81 A/m3, and 4.25 ± 0.55 m3 H2/m3 d, respectively. The results obtained in this study imply that a systematic investigation of the key operational variables is an effective strategy to maximize the hydrogen production in single-chamber MECs.