Title of article :
Pneumothorax Following Feeding Tube Placement: Precaution and Treatment
Author/Authors :
Amirlak، Bardia نويسنده Department of Plastic Surgery, University of Texas, South Western Medical Center, Texas, USA. Amirlak, Bardia , Amirlak، Iradj نويسنده Department of Pediatrics, NMC Specialty Hospital, Al Ain UAE. Amirlak, Iradj , Awad، Ziad نويسنده Department of Surgery, University of Florida, USA. Awad, Ziad , Zahmatkesh، Morteza نويسنده Department of Emergency, NMC Specialty Hospital, Al Ain UAE. Zahmatkesh, Morteza , Pipinos، Irakilis نويسنده Department of Surgery, Creighton University, Nebraska, USA. Pipinos, Irakilis , Forse، R Armour نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی 0 سال 2012
Pages :
4
From page :
355
To page :
358
Abstract :

Nasojejunal feeding tubes are being used at an increased frequency, but it is not without complications that could be life-threatening. We report two cases of pneumothorax following small-bore feeding tube insertion into the pleural cavity, resulting in pneumothorax. We further discuss the potential measures that can be taken to prevent and treat this serious complication.

Journal title :
Acta Medica Iranica
Serial Year :
2012
Journal title :
Acta Medica Iranica
Record number :
2389718
Link To Document :
بازگشت