Title of article :
Effect of type of luting agents on stress distribution in the bone surrounding implants supporting a three-unit fi xed dental prosthesis: 3D fi nite element analysis
Author/Authors :
Ghasemi، Ehsan نويسنده 1Dental Materials Research Center, Department of Prosthodontics , , Abedian، Alireza نويسنده Department of Mechanical Engineering, , , Iranmanesh ، Pedram نويسنده Dentist, School of Dentistry, Isfahan University of Medical Sciences. Isfahan, Iran , , Khazaei، Saber نويسنده of Dentistry, Kermanshah University of Medical Sciences, Kermanshah, Iran ,
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2015
Abstract :
Background: Osseointegration of dental implants is infl uenced by many biomechanical factors
that may be related to stress distribution. The aim of this study was to evaluate the effect of type
of luting agent on stress distribution in the bone surrounding implants, which support a three-unit
fi xed dental prosthesis (FDP) using fi nite element (FE) analysis.
Materials and Methods: A 3D FE model of a three-unit FDP was designed replacing the maxillary
fi rst molar with maxillary second premolar and second molar as the abutments using CATIA V5R18
software and analyzed with ABAQUS/CAE 6.6 version. The model was consisted of 465108 nodes
and 86296 elements and the luting agent thickness was considered 25 ?m. Three load conditions
were applied on eight points in each functional cusp in horizontal (57.0 N), vertical (200.0 N) and
oblique (400.0 N, ? = 120°) directions. Five different luting agents were evaluated. All materials
were assumed to be linear elastic, homogeneous, time independent and isotropic.
Results: For all luting agent types, the stress distribution pattern in the cortical bone, connectors,
implant and abutment regions was almost uniform among the three loads. Furthermore, the
maximum von Mises stress of the cortical bone was at the palatal side of second premolar. Likewise,
the maximum von Mises stress in the connector region was in the top and bottom of this part.
Conclusion: Luting agents transfer the load to cortical bone and different types of luting agents
do not affect the pattern of load transfer.
Journal title :
DRJ Dental Research Journal
Journal title :
DRJ Dental Research Journal