• Title of article

    Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

  • Author/Authors

    Janbabanezhad Toori، A نويسنده School of Medicine, Babol University of Medical Sciences, Babol, Iran , , Shabestani-Monfared، A نويسنده Department of Medical Physics, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran , , Deevband، M R نويسنده Department of Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran , , Abdi، R نويسنده Department of Radiology, Mazandaran University of Medical Sciences, Sari, Iran , , Nabahati، M نويسنده Department of Radiology, Babol University of Medical Sciences, Babol, Iran ,

  • Issue Information
    فصلنامه با شماره پیاپی 0 سال 2015
  • Pages
    8
  • From page
    177
  • To page
    184
  • Abstract
    Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefts of Computed Tomography (CT) are well known in accurate diagnosis, those benefts are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from Computed Tomography (CT) examination in Mazandaran hospitals and defning diagnostic reference level (DRL). Methods: Patient-related data on CT protocol for four common CT examinations including brain, sinus, chest and abdomen & pelvic were collected. In each center, Computed Tomography Dose Index (CTDI) measurements were performed using pencil ionization chamber and CT dosimetry phantom according to AAPM report No. 96 for those techniques. Then, Weighted Computed Tomography Dose Index (CTDIW), Volume Computed Tomography Dose Index (CTDI vol) and Dose Length Product (DLP) were calculated. Results: The CTDIw for brain, sinus, chest and abdomen & pelvic ranged (15.6- 73), (3.8-25. 8), (4.5-16.3) and (7-16.3), respectively. Values of DLP had a range of (197.4-981), (41.8-184), (131-342.3) and (283.6-486) for brain, sinus, chest and abdomen & pelvic, respectively. The 3rd quartile of CTDIW, derived from dose distribution for each examination is the proposed quantity for DRL. The DRLs of brain, sinus, chest and abdomen & pelvic are measured 59.5, 17, 7.8 and 11 mGy, respectively. Conclusion: Results of this study demonstrated large scales of dose for the same examination among different centers. For all examinations, our values were lower than international reference doses.
  • Journal title
    Journal of Biomedical Physics and Engineering
  • Serial Year
    2015
  • Journal title
    Journal of Biomedical Physics and Engineering
  • Record number