Author/Authors :
Saeedimoghadam، M نويسنده Ionizing and Non-Ionizing Radiation protection research center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran; , , Shekoohi Shooli، F نويسنده 3Ionizing and Non-Ionizing Radiation protection research center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran; , , Shokrpour، N نويسنده English department, faculty of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Ira , , Kazempour، M نويسنده Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran; ,
Abstract :
Background: In diagnostic radiology lead apron, are usually used to protect
patients and radiology staff against ionizing radiation. Lead apron is a desirable
shield due to high absorption and effective attenuation of x-ray photons in the
diagnostic radiology range.
Objective: Although lead aprons have good radiation protection properties,
in recent years, researchers have been looking for alternative materials to be
used instead of lead apron because of some problems derived from lead-content
of aprons. Because of its lead-content, these radiation protection garments are so
heavy and uncomfortable for the staff to wear, particularly in long-time uses. In
addition, lead is a toxic element and its disposal is associated with environmental
and human-health hazards.
Method: In this study, several new combinations of lead free materials ((W-Si),
(W-Sn-Ba-EPVC ), (W-Sn-Cd-EPVC)) have been investigated in the energy range
of diagnostic radiology in two geometries: narrow and broad beam. Geometries
of the radiation attenuation characteristics of these materials was assessed in 40,
60, 90 and 120 kVp and the results compared with those of some lead-containing
materials ((Pb-Si), (Pb-EPVC)).
Results: Lead shields still provide better protection in low energies (below 40
kVp). Combination of W-Sn-Cd-EPVC has shown the best radiation attenuation
features in 60 and 90 kVp and the composition of (W-Sn-Ba-EPVC) represents the
best attenuation in 120 kVp, even better than previously mentioned lead- containing composites.
Conclusion: Lead free shields are completely effective for protection against
X-ray energies in the range of 60 to 120 kVp.