• Title of article

    Design of an Optical Sensor for Aluminium(III) Determination Based on Immobilization of Eriochrome Cyanine R on a Triacetylcellulose

  • Author/Authors

    خواجه شريفي، حبيب اله نويسنده Department of Chemistry, College of Sciences, Yasouj University, P. O. Box 7591-874934, Yasouj, Iran Khajehsharifi, Habibollah , صلح جو، آيدا نويسنده Department of Chemistry, College of Sciences, Yasouj University, P. O. Box 7591-874934, Yasouj, Iran Solhjoo, Aida , بردبار، محمدمهدي نويسنده - ,

  • Issue Information
    دوفصلنامه با شماره پیاپی 0 سال 2016
  • Pages
    8
  • From page
    145
  • To page
    152
  • Abstract
    يك حسگر نوري بر پايه‌ نشاندن واكنشگر اريوكروم سيانين‌آر به روي غشا تري استيل سلولز براي اندازه‌گيري يون آلومينيوم (III) طراحي شد. اين حسگر نوري داراي پاسخ برگشت‌پذير و تكرار‌پذير مي‌باشد. در اثر بر همكنش انتخابي اريوكروم سيانين‌آر موجود در غشا با يون‌ آلومينيوم، رنگ غشا از صورتي به بنفش در0/6pH= تغيير مي‌كند. درشرايط بهينه، روش داراي پاسخ خطي غلظت يون‌ آلومينيوم (III) از 8-10×22/3 تا 5-10×10/4 مولار و حد تشخيص آن 8-10×2/1 مولار مي باشد. جزييات محاسبه خطي، حد تشخيص، حساسيت، گزينش پذيري و زمان پاسخ مورد بحث قرار گرفت. پاسخ حسگر وابسته بهpH بود. پاسخ غشا به يون آلومينيوم (III) غير برگشتي و شامل تغيير رنگ از صورتي به آبي بود. غشا از طريق گذاشتن در محلول 1/0 مولار EDTA در كمتر از 30 ثانيه قابل برگشت براي اندازه گيري هاي بيشتر مي باشد. زمان پاسخ غشا كمتر از 16 دقيقه بر حسب غلظت آلومينيوم مي باشد. تكرارپذيري و تكثيرپذيري پاسخ غشا به ترتيب 62/1 و 3 درصد بدست آمد. حسگر پاسخ گزينش پذيري را نسبت به آلومينيوم (III) در مقابل كاتيون هاي ديگر نظير Zn(II)، Cu(II)، Fe(III)، Ni(II) و Co(II) از خود نشان مي دهد. حسگر براي اندازه گيري آلومينيوم (III) در آب هاي شرب و شربت منيزيم-آلومينيوم استفاده شده است.
  • Abstract
    A selective optical sensor based on immobilization of Eriochrome Cyanine R for the determination of Al(III) ions in aqueous solution has been developed. The method is based on the spectrophotometric measurement of complex Eriochrome Cyanine R-aluminium at 537 nm. The sensing membrane is made of a triacetylcellulose film containing Eriochrome Cyanine R colorimetric reagent immobilized as an ion pair with methyltrioctylammonium chloride. The response of the sensor is based on the Eriochrome Cyanine R absorbance decrease by the coordination of Al(III) ions. At pH= 6.0, the linear dynamic rangeis varied from 3.22×10-8 to 4.10×10-5 mol L-1 with a detection limit of 1.2× 10-8 mol L-1. A dynamic working range, detection limit, sensitivity, selectivity and the response time were discussed in detail. The response was pH dependent. The membrane responds to Al(III) ions irreversibly by changing color from pink to blue. The membrane was regenerated in less than 30 seconds with 0.1 mol L-1 EDTA solution and was ready for further measurements. The response time of the sensor was within 16 min depending on the concentration of Al (III) ions. The sensor response was found to have a repeatability and reproducibility of 1.62% and 3%, respectively. The sensor provides appropriate selectivity to Al(III) ions over transition metal cations, including Co(II), Ni(II), Fe(III), Cu(II) and Zn(II). The sensor has been used for the determination of Al(III) ions in potable water and aluminium – magnesium syrup.
  • Journal title
    Iranian Journal of Analytical Chemistry
  • Serial Year
    2016
  • Journal title
    Iranian Journal of Analytical Chemistry
  • Record number

    2396119