Title of article :
The required power of the MGT-40 gas turbine starter
Author/Authors :
Zirak، Saadat نويسنده Faculty of Mechanical Engineering Department Semnan University, Semnan, Iran , , Ebrahimi، Hamid نويسنده Aerospace Department Sharif University Of Technology,Tehran, Iran , , Maissamy، Ahmad Reza نويسنده MapnaTurbine Company (TUGA), Karaj, Iran ,
Issue Information :
دوفصلنامه با شماره پیاپی 0 سال 2015
Abstract :
Determination of the starter torque-speed diagram is a major task in the design or selection of a proper gas turbine starter. In this paper, the maximum power of the MGT-40 gas turbine starter was calculated based on the dynamics of the rotor, start-up logic, and compressor map. In a recent research, the pressure ratio was assumed as a linear function of the rotor speed and the required starter power was calculated. In this study, the value is determined from the field data. To evaluate the proposed method, the results of obtained power were compared with that of the turbine performance reports. The comparison resulted in a reasonable engineering approximation.
Journal title :
Energy Equipment and Systems
Journal title :
Energy Equipment and Systems