Title of article
Direct Chemiluminescence Determination of Oxymorphone Using Potassium Permanganate and Polyphosphoric Acid
Author/Authors
-، - نويسنده Department of Chemistry, Golestan University, Gorgan, IR Iran Koohsarian, Maryam , -، - نويسنده Department of Chemistry, Golestan University, Gorgan, IR Iran Mokhtari, Ali
Issue Information
دوفصلنامه با شماره پیاپی سال 2017
Pages
13
From page
127
To page
139
Abstract
-
Abstract
Abstract A simple and sensitive chemiluminescence (CL) method was developed for direct quantification of oxymorphone, a µ opioid agonist that is approximately 10 times more potent than morphine. In this method potassium permanganate in polyphosphoric acid was used as CL reagent. Using this method, oxymorphone can be determined over the concentration ranges 13.5-337.8 ng mL-1 and 0.34-6.76 µg mL-1 with a sampling rate of 45 samples h−1. The limit of detection was 3.5 ng mL-1 (signal to noise =3) and the percent of relative standard deviations (in 9 replicate measurements) were 3.1% for 135.1 ng mL-1 and 3.6% for 1.4 µg mL-1 oxymorphone. The method is applied to human plasma and synthetic samples. The CL mechanism has been proposed using UV-Vis, fluorescence and CL spectra. In this study, detectability of oxymorphone in some other CL systems such as Ce(IV)-H2SO4, luminol-H2O2, Ru(phen)32+-Ce(IV) and permanganate-SO32- is investigated. CL intensities of twelve narcotics or related drugs were also investigated in the proposed CL system.