• Title of article

    Calculation of Exposure Rate Constant for 60Co, 22Na and 111In Sources with FLUKA Monte Carlo Code

  • Author/Authors

    Khoramian Daryoush نويسنده Department of Medical Physics, Faculty of Medicine, Tarbiat Modares University, Tehran, Iran. , Saba Valiallah نويسنده AJA University of Medical sciences, Tehran, Iran Saba Valiallah

  • Pages
    4
  • From page
    18
  • Abstract
    Exposure rate constant (?) relates activity of a point source to exposure rate at certain distance. It’s an important parameter in radiation protection, medical uses and radiological assessments. In this study exposure rate constant for three radionuclides include 60Co, 22Na and 111In were calculated with FLUKA Monte Carlo method. Each sources simulated and exposure rate at different distances of 20, 30, 40, 60, 80, 100, 120, 150, 200 and 300cm from the sources were measured. For dose measurements we simulate a farmer ionization chamber with active volume of 0.6cm3, inner electrode of aluminium with diameter of1mm and wall of pure graphite with thickness of 0.75mm. Calculated exposure rate constants for 60Co, 22Na and 111In at 20 to 300cm from the source ranged from 33.45 to 0.16 mR/(mCi.h), 29.12 to 0.10 mR/(mCi.h) and 8.73 to 0.03 mR/(mCi.h) respectively which show a decreasing trend. Comparison of our results with other studies show that there are good agreement for 60Co and 22Na, our values for exposure rate constant for 111In was higher than previous reports.
  • Journal title
    Astroparticle Physics
  • Serial Year
    2017
  • Record number

    2408636