Author/Authors :
Durmaz Ufuk نويسنده Assistant Professor , Ozdemir Mustafa نويسنده Associate Professor , Pehlivan Huseyin نويسنده Associate Professor
Abstract :
The raw milk is an important basic material for many food products. Fresh
milk must be cooled immediately after milking to keep high quality and processability. In
this work, the overall heat transfer coecients of the milk cooling vessels used for this
purpose have been studied experimentally. This study is aimed at determining the overall
heat transfer coecients of cooling vessels, which have dierent types and capacities without
freezing and churning to avoid separation of milkʹs fat. Vessels are used ranged as follows:
300-500-1000-1500-1850-2000 liters for verticals and 2000-2500-3000-4000-5000-6000 liters
for horizontals. It is found that the theoretical calculations are in satisfactory agreement
with the experimental data. As a result of investigation, the overall heat transfer coecient
can be written in relation to power intensity for horizontal vessels. It is a certain constant
value for vertical ones.