Tajik-Mansoury, Mohammad Ali Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran , Rajabi, Hossein Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran , Mozdarani, Hossein Department of Medical Genetics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran
Abstract :
Introduction: Spatial dose distribution around the radionuclides sources is required for optimized treatment planning in
radioimmunotherapy. At present, the main source of data for cellular dosimetry is the s-values provided by MIRD. However,
the MIRD s-values have been calculated based on analytical formula in which no electrons straggling is taken to account. In
this study, we used Geant4-DNA Monte Carlo toolbox to calculate s-values and the results were compared to the
corresponding MIRD data.
Methods: Similar to MIRD cell model, two concentric spheres representing the cell and its nucleus were used as the
geometry of simulation. The cells were assumed to be made of water. Cellular s-values were calculated for three beta emitter
radionuclides 131I, 90Y and 177Lu that are widely used in radioimmunotherapy. Few lines of code in C++ were added into
Geant4-DNA codes to automatically calculate the s-values and transfer data into excel files.
Results: The differences between two series of data were analyzed using Pearson’s correlation and Bland-Altman curves.
We observed high correlation (R2>0.99) between two series of data for self-absorption; however, the agreement was very
weak and Wilcoxon signed rank test showed significant difference (p-value<0.001). In cross-absorption, Bland-Altman
analysis showed a considerable bias between MIRD s-values and corresponding Geant4-DNA data. The percent differences
between the data were -79% to +67%.
Conclusion: Results of the comparison show a reflection of systematic error rather than statistical fluctuation. The
inconsistency is most probably associated with the neglecting of straggling and δ-ray transport in MIRD analytical method.
Keywords :
Cellular S-value , Geant4-DNA , MIRD , Beta emitter , Radionuclides