Fallah Tafti, Mohammadreza Eye Research Center - Farabi Eye Hospital - Tehran University of Medical Sciences , Heidarian, Shahab Eye Research Center - Farabi Eye Hospital - Tehran University of Medical Sciences , Kiarudi, Mohammad Yaser Eye Research Center - Farabi Eye Hospital - Tehran University of Medical Sciences , Mohammadpour, Mehrdad Eye Research Center - Farabi Eye Hospital - Tehran University of Medical Sciences , i Nasab, Mercede Majd Eye Research Center - Farabi Eye Hospital - Tehran University of Medical Sciences
Abstract :
Purpose: To investigate the validity of Pentacam derived parameters like corneal volume
distribution and percentage increase in volume in differentiation of mild to moderate keratoconus
from normal corneas
Methods: Forty eyes with mild to moderate keratoconus and 200 normal eyes were studied by
Pentacam. Corneal volume was calculated within diameters from 1.0 to 7.0 mm with 0.5 mm steps
centered on the thinnest point to create the corneal volume distribution. The percentage increase
in volume was calculated for each position of the corneal volume distribution from their first value.
Statistical analysis was done using the Mann-Whitney test to compare mean levels of two groups
and the Wilcoxon test for two consecutive measurements.
Results: Statistically significant differences were observed between the keratoconic and normal
corneas (P<0.01) in all positions of corneal volume distribution and in the percentage increase in
volume. The differences between the curves of the two groups were more significant in 3 mm
diameter and further.
Conclusion: There are significant difference between corneal volume distribution and percentage
increase in volume in keratoconic and normal corneas and could serve as valid indices to diagnose
mild and moderate forms of keratoconus.