Determination of the Optimal Angle for Needle Insertion During Caudal Epidural Steroid Injection in Adults Using Ultrasound Imaging
Author/Authors :
Gökçek, Erhan Department of Anesthesiology and Reanimation - Diyarbakır Selahaddin Eyyübi State Hospital - Diyarbakir, Turkey , Kaydu, Ayhan Department of Anesthesiology and Reanimation - Diyarbakır Selahaddin Eyyübi State Hospital - Diyarbakir, Turkey
Abstract :
Background: Lumbar back pain is a common disease, which reduces life quality. Caudal epidural steroid injection (CESI) is frequently
preferred to relieve lumbar back pain. However, various major complications can be observed due to CESI. A new technique
of needle angle should be improved to prevent complications such as intraosseous, intrathecal or intravascular injection during
CESI.
Objectives: Caudal epidural steroid injection is one of the methods frequently used to treat chronic lumbar back pain. The current
study aimed at examining the anatomy of the sacral hiatus and determining the optimal angle of the needle for CESI.
Methods: The current clinical trial was performed in Diyarbakır Selahaddin Eyyübi State Hospital from January to June in 2017. The
study included 150 adult patients (first group = 92 males (%61.3), second group = 58 females (%38.7) aged 18 - 78 years applied to the
Algology Polyclinic with ASA-PS classes I and II (the American Society of Anesthesiologists (ASA) physical status classification system).
Measurements were taken during the CESI applied under ultrasonography (USG) guidance of the intercornual distance, the sacral
space, and the optimal needle entry angle.
Results: The intercornual distance was significantly higher in group one (meanstandard deviation (SD): 16.62.04) than group
two (meanSD: 15.82.51) (P < 0.049). No difference was observed between group one (meanSD: 4.490.75) and group two
(meanSD: 4.450.88) with respect to sacral space (P > 0.79). The most appropriate entry angle for the needle in the application
of CESI was mean 71.04° in the whole patient group, as 71.9° in group one and 69.7° in group two. There was no significant difference
between the genders in terms of themeanoptimal angle (P> 0.091). Also, nosignificant difference was observedamongthe patients
in terms of the demographic data (P > 0.05).
Conclusions: The results of the current study revealed that the optimal needle angle for CESI applied under USG guidance was
71.04°, different from traditional method and the injection procedure could be safely made directly to the epidural space without
changing the angle after entry of the needle to the epidural space.