• Title of article

    Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes

  • Author/Authors

    Feizi, Sepehr Shahid Beheshti University of Medical Sciences, Tehran , Delfazayebaher, Siamak Shahid Beheshti University of Medical Sciences, Tehran , Javadi, Mohammad Ali Shahid Beheshti University of Medical Sciences, Tehran , Karimian, Farid Shahid Beheshti University of Medical Sciences, Tehran , Ownagh, Vahid Shahid Beheshti University of Medical Sciences, Tehran , Sadeghpour, Fatemeh Shahid Beheshti University of Medical Sciences, Tehran

  • Pages
    8
  • From page
    93
  • To page
    100
  • Abstract
    Purpose: To compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. Methods: A total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. Mean posterior corneal power and astigmatism were measured using a dual Scheimpflug camera. Correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. Receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. Results: The mean posterior corneal power was −6.29 ± 0.20 D in the normal group and −7.77 ± 0.87 D in the keratoconus group (P < 0.001). The mean magnitudes of the posterior corneal astigmatisms were −0.32 ± 0.15 D and −0.94 ± 0.39 D in the normal and keratoconus groups, respectively (P < 0.001). Significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=−0.76, P < 0.001) and keratoconus (r=−0.72, P < 0.001) groups. The mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). The optimal cut-off points of mean posterior corneal power and astigmatism were −6.70 D and −0.54 D, respectively. Conclusion: Mean posterior corneal power and astigmatism measured using a Galilei analyzer camera might have potential in diagnosing keratoconus. The cut-off points provided can be used for keratoconus screening.
  • Keywords
    Keratoconus , Posterior Corneal Astigmatism , Posterior Corneal Power
  • Journal title
    Astroparticle Physics
  • Serial Year
    2018
  • Record number

    2431888