Title of article :
SYSTEMIC TOXICITY REACTIONS DUE TO EPIDURAL CATHETER DISPLACEMENT
Author/Authors :
Ghafari, M.H Department of Anesthesiology - School of Medicine - Tehran University of Medical Sciences - Tehran, Iran , Akrami, M. Department of Anesthesiology - School of Medicine - Tehran University of Medical Sciences - Tehran, Iran , Sadeghi, M Department of Anesthesiology - School of Medicine - Tehran University of Medical Sciences - Tehran, Iran , Ghoreishinejad, M Department of Anesthesiology - School of Medicine - Tehran University of Medical Sciences - Tehran, Iran
Pages :
3
From page :
518
To page :
520
Abstract :
Toxic reactions to local anesthetics may occur due to over dose, accidental intravenous injections or rapid systemic uptake of the drugs. But there have been few reports on toxicity due to displacement of epidural catheters after an initial correct insertion and performance of a test dose. Here we present a case of local anesthetics toxicity due to possible displacement of the epidural catheter during APR (Ant-post Colporrhaphy) surgery. The patient’s level of consciousness decreased at the end of surgery. She demonstrated CNS and cardiovascular toxicity due to local anesthetics. Consequently the patient was intubated and transferred to ICU, where she received mechanical ventilation along with other supportive treatments such as inotropic and antiepileptic drugs. We concluded that supportive therapy is the treatment of choice for such cases.
Keywords :
local anesthetics , toxic reaction , Epidural catheter
Journal title :
Astroparticle Physics
Serial Year :
2008
Record number :
2446317
Link To Document :
بازگشت