Title of article :
Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Author/Authors :
Afshar ، Ahmadreza - Urmia University of Medical Sciences
Abstract :
During fixation of a femoral neck fracture in a 23yearold male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementation of orthopedic instruments and increases patient’s safety during surgery.
Keywords :
Cannulated screw , complication , femoral neck fracture , Guide wire , Patient’s Safety
Journal title :
The Archives of Bone and Joint Surgery
Journal title :
The Archives of Bone and Joint Surgery