Abstract :
One of the causes of perturbation at vertical intakes is the happening of vortices with an air core. The vortices with an air core occur whenever the submergence of the intake is less than a critical value. Antivortex devices and specially plates are used to avoid the negative effects of the aircore vortices. If plates are used, then the geometry of them should be studied experimentally. Accordingly, a precise set of experiments have been carried out using rectangular plates with different dimensions. The results showed that using the vertical plates can increase the critical submergence for the same discharge rates to 51%.
Keywords :
Vertical Intake , AntiVortex Device , Submergence of Intake , AirCore Vortices , Discharge Rate