Title of article
Discharge Coefficient in Vertical Intakes with Additional Plates
Author/Authors
Naderi ، Vadoud - Tabriz University , Farsadizadeh ، Davood - Tabriz University , Hossein Zadeh Dalir ، Ali - Tabriz University , Arvanaghi ، Hadi - Tabriz University
Pages
10
From page
23
To page
32
Abstract
One of the causes of perturbation at vertical intakes is the happening of vortices with an air core. The vortices with an air core occur whenever the submergence of the intake is less than a critical value. Antivortex devices and specially plates are used to avoid the negative effects of the aircore vortices. If plates are used, then the geometry of them should be studied experimentally. Accordingly, a precise set of experiments have been carried out using rectangular plates with different dimensions. The results showed that using the vertical plates can increase the critical submergence for the same discharge rates to 51%.
Keywords
Vertical Intake , AntiVortex Device , Submergence of Intake , AirCore Vortices , Discharge Rate
Journal title
journal of hydraulic structures
Serial Year
2013
Journal title
journal of hydraulic structures
Record number
2451119
Link To Document