• Title of article

    Studying the Effect of Kidney Internal Structure on Beta Absorbed Dose of Radiopharmaceuticals Hg203, Ho166 And Y90 Using Monte Carlo

  • Author/Authors

    Mirzaei ، Mohammad - Technical and Vocational University

  • Pages
    7
  • From page
    1040
  • To page
    1046
  • Abstract
    Large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. Therefore, radiation unwanted dose is created in kidney. As a result, exact calculation of prescribed radiopharmaceuticals amount is important. Monte Carlo method is used for simulation of radiation transport in body due to random nature of radiation. In this research, for the first time kidney is considered integrated and for the second time it is considered that it has three areas; beta absorbed dose is calculated and compared in cortex and medulla kidney using MCNPX code to identify a more accurate way to prescribe radioisotope. The results showed that beta absorbed dose in medulla is 4 times as much as dose in integrated kidney and beta dose in cortex is 0.004 to 0.012 times as much as dose in integrated kidney. Internal structure of kidney should be considered in simulation to achieve a more accurate prescribed dose
  • Keywords
    Absorbed dose , Medulla , Cortex , Monte Carlo method
  • Journal title
    International Journal of Advanced Biological and Biomedical Research
  • Serial Year
    2013
  • Journal title
    International Journal of Advanced Biological and Biomedical Research
  • Record number

    2458201