Author/Authors :
Mothilal, T Department of Mechanical Engineering - Velammal Institute of Technology, Chennai, Tamil Nadu, India , Pitchandi, K Department of Mechanical Engineering - Sri Venkateswara College of Engineering, Sriperumbudur, Tamil Nadu, India , Velukumar, V Department of Mechanical Engineering - T J S Engineering College, Peruvoyal, Chennai Tami Nadu, India , Parthiban, K Department of Mechanical Engineering - T J S Engineering College, Peruvoyal, Chennai Tami Nadu, India
Abstract :
Present work optimizes the operational parameters such as solid particle diameter, inlet air velocity and inlet
air temperature on heat transfer rate by Taguchi method. Operational parameters play an important role in the
performance of cyclone heat exchanger thus the parameter optimization is deemed important. The parameters
have been analyzed under varying solid particle diameter (300 and 400 μm), inlet air temperature (323, 373,
423 and 473 K) and inlet air velocity (5, 10, 15 and 20 m/s). Results of heat transfer rate by varying the
operational parameters have been found from Computational Fluid Dynamics (CFD) software Ansys Fluent.
Orthogonal array of Taguchi, the signal-to-noise ratio and analysis of variance have been employed to found
the optimal parameter values and the effect of parameters on heat transfer rate. Mixed level factor and L32
array is chosen for the design of analysis in Taguchi. Result of statistical analysis shows that the developed
approach yields worthy results when comparing with predicted simulation values with confidence level of
99.5%. Taguchi analysis reveals that optimized levels of parameters are 300 μm, 473 K & 20 m/s for solid
particles diameter, inlet air temperature and inlet air velocity respectively. Confirmation test was conducted in
simulation and experiment for optimized parameters and result shows that maximum heat transfer rate was
obtained with optimized parameter among the chosen operational parameters.
Keywords :
Cyclone heat exchanger , Taguchi method , CFD , Optimization