Author/Authors :
Akbari, S Electric Railway Department - MAPNA Group, Tehran, Iran , Rosami, Z ALZAHRA University, Tehran , Khoshharf, A Electric Railway Department - MAPNA Group, Tehran, Iran , Fazel, S. S School of Railway Eng. - Iran University of Science and Technology, Tehran
Abstract :
General faults in regular electric railway systems can be detected by
implementing the specific protection functions such as ground fault or
sensitive earth fault. Otherwise, in ungrounded electric railway systems
which are using both feeding and return contact rails at the same time, fault
detection cannot be performed with the above-mentioned function. Due to
recent growth in electric railway networks especially in metropolises, it is
an essential requirement to improve operation and safety indexes by using
efficient fault preventing and fault clearing method in minimum time.
In this research, a new fault diagnosing method is developed by using
frequency response of contact rail system. This technique is based on
observing pattern changes that are caused by some expected faults such as
the broken contact rail, contact rail to ground faults on feed or return circuit
frequency response.
Keywords :
Frequency response , Contact rails , Fault diagnosis , Ungrounded electric railways