Title of article
Validity and reliability of the Persian version of the confusion assessment method for intensive care units
Author/Authors
Arbabi ، Mohammad - Tehran University of Medical Sciences , Zolfaghari ، Mitra - Tehran University of Medical Sciences , Amirsardari ، Anahita - Iran University of Medical Sciences , Fahimfar ، Noushin - Tehran University of Medical Sciences , Eybpoosh ، Sana - Pasteur Institute of Iran
Pages
10
From page
123
To page
132
Abstract
Background Aim: Delirium is prevalent in the intensive care unit (ICU), especially among mechanicallyventilated patients. Delirium is associated with a significant increase in adverse outcomes but it usually remains undiagnosed, making it necessary to develop and validate diagnostic tools. This study determined the validity and reliability of the Persian version of the Confusion Assessment Method for Intensive Care Units) CAM_ICU( in Iran. #xD; Methods #xA0; #xA0;Materials: This crosssectional study was conducted in openheart ICU of three university hospitals of Tehran, Iran. After piloting the translated CAMICU on 10 patients and refining the translated scale accordingly, 40 ventilated patients were consecutively selected and screened for delirium by two independent evaluators (applying CAMICU), and one psychiatrist (using DSMIV criteria for diagnosis). Interrater reliability between the two evaluators was assessed by the Kappa coefficient. Validity indices (i.e., sensitivity and specificity) of the PersianCAMICU and 95% confidence intervals were calculated, given the psychiatrists #x2019; diagnosis as the reference standard. Data were analyzed in Stata software (v. 11). #xD; Results: Of 40 selected patients, CAM_ICU detected delirium in 30%. The PersianCAMICU had a sensitivity and specificity of 75% and 96%, and a positive and negative predictive value of 92% and 85%, respectively. Youden #x2019;s J statistic of the scale was 71%. Each of the four domains of the CAMICU showed a sensitivity and specificity of more than 69% and 90%, respectively, suggesting acceptable construct validity. There was good agreement between the two evaluators in terms of delirium diagnosis with the PersianCAMICU (kappa coefficient = 0.74, P lt;0.0001). #xD; Conclusion: The Persian version of the CAM_ICU is an effective, valid and reliable diagnostic tool in critically ill ICU patients. Application of the scale is recommended for the prompt diagnosis and prevent potential delirium in ventilated patients.
Keywords
delirium , intensive care units , confusion , CAMICU , Iran
Journal title
Nursing Practice Today
Serial Year
2019
Journal title
Nursing Practice Today
Record number
2470031
Link To Document