• Title of article

    Cytotoxicity Evaluation of The Bioresorbable and Titanium Plates/Screws Used in Maxillofacial Surgery on Gingival Fibroblasts and Human Mesenchymal Bone Marrow Stem Cells

  • Author/Authors

    Vatani ، Masoud - Islamic Azad University, Khorasgan Branch , Beigi ، Mohammad Hossein - Academic Center for Education, Culture and Research (ACECR) , Ejeian ، Fatemeh - Academic Center for Education, Culture and Research (ACECR) , Mottaghi ، Ahmad - Islamic Azad University, Khorasgan Branch , Yadegari-Naeini ، Afshin - Islamic Azad University, Khorasgan Branch , Nasr-Esfahani ، Mohammad Hossein - Academic Center for Education, Culture and Research (ACECR)

  • Pages
    9
  • From page
    310
  • To page
    318
  • Abstract
    Objective: Bioresorbable and titanium plates/screws are considered as a standard treatment for fixation of the bone segments of craniofacial area and paying attention to their biocompatibility is an important issue along with other aspects of application. The purpose of the study was to evaluate the cell viability of two types of plate and screw used in maxillofacial surgeries in contact with gingival fibroblasts and bone marrow stem cells. Materials and Methods: In this experimental study after extraction and cultivation of cells from healthy human gingival tissue and alveolar bone of jaw, cytotoxicity of device was evaluated. In direct contact method, samples had near vicinity contact with the both cell lines and in indirect contact method, by-products released, like ions, from samples after 8 weeks were used to assess cytotoxicity. Then cytotoxicity was evaluated on the 2nd, 4th and 6th day with MTS tests and microscopy. The data were analyzed by one-way ANOVA and independent t tests. Results: There was a statistically significant difference between the German plate and screw and all the samples studied on day 6 (P 0.05). Furthermore, a statistically significant difference was observed between both metal samples and both bio-absorbable samples on day 6 and both cell lines (P 0.05). Comparisons between the two groups with each other for both cell lines on the 6th day were statistically significant (P 0.05). Conclusion: Our results suggest that that cytotoxicity of biomaterial, from different brands, were not similar and some of the biomaterial showed lower degree of toxicity compared to others and specialist using these products showed be aware of this differences. Our investigation indicates more biocompatibility of bioresorbable plates and screws compared to titanium. In addition our results suggest that biomaterials were not completely neutral.
  • Keywords
    Bone Marrow Stem Cell , Cytotoxicity Test , Dental Implant Materials , Fibroblast Cells
  • Journal title
    Cell Journal(Yakhteh)
  • Serial Year
    2020
  • Journal title
    Cell Journal(Yakhteh)
  • Record number

    2470069