Title of article :
Seismic Demand Evaluation of Elevated Reinforced Concrete Water Tanks
Author/Authors :
Shakib ، H. - Tarbiat Modares University , Omidinasab ، F. - Tarbiat Modares University , Ahmadi ، M.T. - Tarbiat Modares University
Pages :
17
From page :
204
To page :
220
Abstract :
Elevated water tanks as one of the main lifeline elements are the structures of high importance. Since they are extremely vulnerable under lateral forces, their serviceability performance during and after strong earthquakes is a matter of concern. As such, in recent years, the seismic behavior of water tanks has been the focus of a significant amount of studies. In the present work, three reinforced concrete elevated water tanks, with a capacity of 900 cubic meters and height of 25, 32 and 39 m were subjected to an ensemble of earthquake records. The behavior of concrete material was assumed to be nonlinear. Seismic demand of the elevated water tanks for a wide range of structural characteristics was assessed. The obtained results revealed that scattering of responses in the mean minus standard deviation and mean plus standard deviation are approximately 60% to 70 %. Moreover, simultaneous effects of mass increase and stiffness decrease of tank staging led to increase in the base shear, overturning moment, displacement and hydrodynamic pressure equal to 10 20 %, 13 32 %, 10 15 % and 8 9 %, respectively.
Keywords :
Elevated water tank , Seismic demand , Ensemble earthquake records
Journal title :
International Journal of Civil Engineering
Serial Year :
2010
Journal title :
International Journal of Civil Engineering
Record number :
2471845
Link To Document :
بازگشت