• Title of article

    Foreign body associated non-ST elevation myocardial infarction: a case report

  • Author/Authors

    Dehghani ، Pooyan - Shiraz University of Medical Sciences , Sajedi Khanian ، Mahdi - Shiraz University of Medical Sciences

  • Pages
    3
  • From page
    229
  • To page
    231
  • Abstract
    The incidence of guiding catheter tip fracture, is quite rare during percutaneous coronary interventions (PCI). Retained broken catheter tip in coronary artery and circulation can result in serious complications such as thrombosis, embolism, acute occlusion and myocardial infarction, arrhythmias and sepsis. It is mandatory to remove the fractured catheter as soon as possible to avoid these complications. Transcatheter removal is the treatment of choice. If percutaneous removal is failed, surgical intervention is advised.
  • Keywords
    Foreign Body , Broken Guiding Catheter Tip , Non , ST Elevation Myocardial Infarction