Title of article :
Ethylenedicysteine Versus Diethylenetriamine Pentaacetic Acid as the Carrier of Technetium Tc 99m in Diuretic Renography for Patients with Upper Urinary Tract Obstruction
Author/Authors :
Shahrokh, Hossein Department of Urology - Hasheminejad Hospital - Iran University of Medical Sciences, Tehran , Movahhed, Mansour Department of Urology - Hasheminejad Hospital - Iran University of Medical Sciences, Tehran , Zargar Shoshtari, Mohammad Ali Department of Urology - Hasheminejad Hospital - Iran University of Medical Sciences, Tehran , Orafa, Amir Mohammad Department of Urology - Hasheminejad Hospital - Iran University of Medical Sciences, Tehran , Hekmat, Sepideh Department of Urology - Hasheminejad Hospital - Iran University of Medical Sciences, Tehran
Pages :
7
From page :
97
To page :
103
Abstract :
Introduction: L,L-ethylenedicysteine (EC) is a new carrier of technetium Tc 99m (99mTc) with a lower affinity to plasma albumin in comparison with diethylenetriamine pentaacetic acid (DTPA). We compared 99mTc-EC scan with 99mTc-DTPA scan in diuretic renography for patients with obstructive uropathy. Materials and Methods: Thirty-three patients with upper urinary tract obstruction were randomly selected and underwent diuretic renographies by 99mTc-EC and 99mTc-DTPA. The counts of radioisotope per pixel in the target (the kidney) and background tissues as well as the clearance half-life of these two radiopharmaceuticals were measured and compared. Results: Mean counts of radioisotope per pixel in the target tissue was not different between 99mTc-EC and 99mTc-DTPA scans, but in the background tissue, it was less for 99mTc-EC (P = .003). Target-background ratio was higher for 99mTc-EC scan (3.80 ± 2.11 versus 2.48 ± 1.39; P < .001). Renal clearance half-life of radioisotope was shorter for 99mTc-EC scan than 99mTc-DTPA scan (58.15 ± 15.17 minutes versus 78.65 ± 19.99 minutes; P = .033). The results were similar for uremic patients (with a serum creatinine level > 2mg/dL). Conclusion: Target-background ratio of radiopharmaceutical uptake rates in diuretic renography was a good indicator of the higher resolution of 99mTc-EC than 99mTc-DTPA scan. We also demonstrated the faster clearance of 99mTc-EC than 99mTc-DTPA. This results in less radiation that is especially useful in children. To our opinion, 99mTc-EC can better depict the kidneys in comparison with 99mTc-DTPA.
Keywords :
radioisotope renography , kidney function , diethylenetriamine pentaacetic acid , L,L-ethylenedicysteine , radiopharmaceutical , ureteral obstruction
Journal title :
Astroparticle Physics
Serial Year :
2006
Record number :
2485725
Link To Document :
بازگشت