Title of article :
Use of Four-Color Flow Cytometric Assay for Discrimination of Hematogone from Lymphoblast: Critical Issue for MRD Assessment in B-ALL Patients
Author/Authors :
Allahbakhshian Farsani, Mehdi Department of Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Shahabi Satlsar, Esmaeil Department of Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Mohseni, Alireza Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Mazandaran University of Medical Sciences, Sari, Iran , Mosleh, Mohammad epartment of Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Mehrpouri, Mahdieh epartment of Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Agaeipour, Mahnaz Takhte Tavous Pathobiology Laboratory - Flow Cytometry Department, Tehran, Iran , Mohammadi, Mohammad Hossein Department of Laboratory Hematology and Blood Banking - Faculty of Paramedical Sciences - Shahid Beheshti University of Medical Sciences, Tehran, Iran , Gholampour, Roohollah Takhte Tavous Pathobiology Laboratory - Flow Cytometry Department, Tehran, Iran , Jadali, Farzaneh Takhte Tavous Pathobiology Laboratory - Flow Cytometry Department, Tehran, Iran
Abstract :
Background: Hematogones are normal B-cell precursor which can be seen in different physiological and
pathological conditions. Due to variation in B-cell acute lymphoblastic leukemia (B-ALL) blasts
immunophenotyping and interference of hematogones in minimal residual disease (MRD) assessment, precise
discrimination of hematogones is very crucial. The purpose of this study was to evaluate the expression pattern
of surface markers in hematogones and compare them with lymphoblasts.
Material and Methods: In this applied study, flow cytometric analysis was performed using Coulter FC-500
and MXP software in 4-color combination and 6 different tubes. In this study, 85 patients diagnosed with acute
lymphoblastic leukemia were evaluated. Out of these patients, 45 were boys and 40 were girls. Patients aged
from 1 to 15 years old. In addition, 27 bone marrow samples from other patients aged 4 to 18 years were
included in this investigation. These samples had been obtained for other diagnostic purposes, such as immune
thrombocytopenic purpura and juvenile idiopathic arthritis.
Results: During flow cytometric analysis, hematogones showed expressions of CD19, CD20, CD22, CD10,
CD45, CD81, CD123, CD9, CD34 (partial expression), and tdt (partial expression). In these patients,
hematgones were negative for CD66c expression. Lymphoblastic cells were positive for CD19, CD20 (in some
cases), CD22, CD10, CD45, CD81, CD123, CD58, CD9, CD66c, CD34 (in most cases), and TDT. CD81 mean
fluorescence intensity (MFI) in hematogones was higher than that in lymphoblasts. (112.5 (30-251) vs. 17.5 (5-
30); P<0.0001)
Conclusion: According to findings of this study, it seems that the use of CD81, CD58, CD123, CD66c, CD9,
and CD81 MFI in combination with B-Cells associated markers can be very effective in differentiating
hematogone from lymphoblast.
Keywords :
MRD , Lymphoblast , Hematogone , B-ALL
Journal title :
Astroparticle Physics