Abstract :
An efficient and quantitative two phase freezing (TPF) method coupled with high
performance liquid chromatography and UV-Vis detector was developed for the extraction,
clean up, and determination of clomiphene citrate (CLC) in plasma samples. The separation
of two miscible solvents by TPF method permits that the CLC was efficiently removed from
proteins and transferred into the relative aprotic dipolar organic phase and in consequence, gave
a higher recovery. The TPF method was compared to conventional liquid-liquid extraction and
it gave more clean solution with better reproducibility. Linear range, limit of detection, and
limit of quantification for CLC in plasma were obtained in the range of 0.06-18, 0.02, and
0.06 μg mL-1, respectively. The intraday and interday reproducibility for concentration of 1.0
μg mL-1 (%RSD) were 3.2% and 4.6%, respectively. In addition, the trueness, ruggedness,
and reality of TPF were assessment. Finally, several real plasma samples were successfully
analyzed using the developed method.
Keywords :
Plasma extraction , Doping control , Liquid-liquid extraction , Two phase freezing method , Clomiphene citrate